Full automatic small pets carcass incinerator for dogs and cows
1. Incinerator description:
Dead animal carcass shredder (crusher ) is suitable for harmless treatment of sick animals poultry livesotck carcass . cattles. sheep. cow . pig .chicken and ducks so on .
|
2.Incinerator struction description :
Feeding system (hydraulic feeding device.manual feeding door). Horizontal furnace body. Secondary combustion chamber. Cyclone dust collector (castable); Water cooling device; Microporous ceramic dust collector; Activated carbon spraying device; Flue gas mixer; Lime powder spraying device; Spray washing tower; Induced draft fan. Independent chimney; The burner. Oil groove and pipeline; Oxygen blower and air supply system; Combustion chamber temperature automatic control system; Electric control system; Operating platform and climbing ladder; Connecting flue; Other connecting parts and supporting parts, etc.
|
3. Aplication :
Incinerator are widely used for dead animals .poultry and livestock. cows . pigs . Hospital medical waste . kictchen waste . domestic waste . plastic waste . and industrial solid waste so on.
|
4. Incinerator image:
5.Incinerator features :
1 |
Automatic electrification control system is adopted to improve the degree of automation |
2 |
The overall outer wall of the first combustion chamber and the second combustion chamber adopts domestic high-end anti-corrosion and temperature insulation materials, and the external temperature of the furnace body is less than or equal to 35 degrees. |
3 |
The whole casting structure of one combustion chamber and two combustion chamber is adopted. Other equipment is assembled to facilitate installation and maintenance
|
6. Pay attention :
1 |
The incinerator is equipped with safety protection device, which can automatically cut off the fuel supply and stop the operation of the equipment when the ignition is abnormal after the burner is started. |
2 |
Before stopping operation, the device has the detection of the combustion chamber cooling program, so that when the combustion chamber temperature drops to the set temperature, the incinerator stops all operation. |
3 |
There is a connection protection device between the control cabinet and the control equipment to avoid leakage. When the relative temperature is 85%, the insulation resistance of the electrical circuit is not less than 2M ω, and there is a grounding line to transmit leakage power. The wire is protected by a metal hose. |
4 |
The electronic control system is not only closed-loop control of the combustion temperature of the combustion chamber, closed-loop control of their oxygen supply, coordination of the control between them, so that the control results of the system and the control of each process can meet the requirements, so that the whole system is in closed-loop control. |
7.Basic parameter :
A*
Type |
Capacity |
Covers square meter |
Electric consumption |
Diesel fule consumption |
Working lifetime |
A500 |
500kg/h |
15--20m² |
4/h |
8.25kg/h |
15 years |
B*
Type |
Capacity |
Inner chamber dimension |
Burning temperature |
Surface dimension |
Working lifetime |
A200 |
200kg/h |
1100*1500mm |
1100 degree |
8.25kg/h |
15 years |
C*
Type |
Capacity |
Main chamber diemension |
Secondary chamber diemension |
Cyclone dust removal diemension |
Working lifetime |
A400 |
400kg/h |
Dia1700mm* Height 3.5m |
1.5*1.0*0.8 |
Dia.1000mm*Height |
15 years |
D*
Type |
Capacity |
Working time |
Feeding way |
Fuel |
Working lifetime |
A300 |
300kg/h |
24h/Day |
Hydraulic automatic feeing |
Diesel or natural gas |
15 years |
8.Workshop shows :
9.Customers visit our factory:
10.Factory introduct :
11. Certification