Hospital Garbage Microwave Treatment for Medical Waste Disposal Vehicle Equipment
This equipment can handle medical waste such as medical infection, injury and pathology, and carry out harmless disposal of medical waste. Equipment integrated design, a full set of equipment low energy consumption, automatic operation, simple operation, anytime and anywhere treatment of medical waste, fixed, mobile can be customized according to demand, convenient and flexible.
Microwave disinfection treatment system is an integrated equipment, the equipment at least by automatic feeding unit, airtight bin unit, multi-function airtight crushing unit, negative pressure pumping unit, microwave disinfection sterilization bin unit, microwave generator unit, steam heating system, discharging unit, automatic control unit, waste gas treatment unit 10 units and alarm system.
Microwave sterilization is the result of the joint action of microwave thermal effect and biological effect,so that microwave can directly interact with bacteria,fast sterilization.
1.The thermal effect of microwave energy:under the action of a certain intensity of microwave field,bacteria will absorb microwave energy due to the polarization of molecules,thus making Protein and Physiologically active substance deforms and loses its biological activity.The thermal effect of microwave mainly plays the role of rapid warming and sterilization.
2.Non-thermal effect of microwave energy:the high frequency electric field changes the structure of polarized molecules,leading to protein and physiological active substances in the microbial body mutation and loss of vitality or death,in the sterilization of conventional physical sterilization has no special role.
1.Energy Saving:Microwave heating is uniform,no energy loss,high energy,strong penetration of the object,instantaneous penetration into the object,good energy saving effect,take the daily processing capacity of 5T/D model as an example,installed power is 117kw.
2.Low operating temperature and slow heat loss:if microwave and the ordinary heating have the same amount of sterilization effect,the temperature on the object is obviously lower than that of ordinary heating.Waste after microwave sterilization,no residue,light damage.
3.Non-selective effect on organisms:microwave has the same effect on organisms without selectivity,and its wide spectrum of bacteria can kill all kinds of microorganisms and pathogens.
4.Microwave sterilization requires a small working environment and occupation area,the surrounding environment does not constitute high temperature,clean and hygienic.
No. |
System unit |
Item |
Technical Parameters |
Remark |
Model |
ZT-MWT-3000 |
ZT-MWT-5000 |
ZT-MWT-10000 |
|
1 |
Hoisting System
|
Garbage can |
660L |
660L |
660L |
|
Power source |
4kw hydraulic system |
4kw hydraulic system |
4kw hydraulic system |
|
Material |
Stainless steel |
Stainless steel |
Stainless steel |
|
2 |
Stock bin |
Volume |
1m³ |
1.2m³ |
1.2m³ |
|
Material |
Stainless steel |
Stainless steel |
Stainless steel |
|
Eccentric swage
|
Equipped |
Equipped |
Equipped |
|
3 |
Crushing system |
Power |
22kw |
30kw |
30kw |
|
Blade |
Φ345*30 D550 |
Φ345*30 D550 |
Φ345*30 D550 |
|
4 |
Sterilization chamber |
Power |
2.2kw |
3kw |
3kw |
|
Chamber size |
530-5000 |
530-6000 |
530-8500 |
|
Microwave generator
|
1.1kw*8 |
1.1kw*10 |
1.1kw*20 |
|
5 |
Discharge screw |
Power |
3kw |
3kw |
3kw |
|
6 |
Main body dimension (excluding hoist and discharge screw) |
7000*2900*2650 |
8000*2900*2650 |
10500*290*2650 |
|
7 |
Supporting facility |
Steam generator, water chiller, water softener, electric control box, exhaust equipment (optional), etc |
|
8 |
Total power |
97kw |
130kw |
176kw |
|
9 |
Total Weight |
11000kg |
13000kg |
15000kg |
|
10 |
Capacity(t/h) |
3 |
5 |
10 |
|
Equipment characteristics
1 |
Energy Saving:Microwave heating is uniform,no energy loss,high energy,strong penetration of the object,instantaneous penetration into the object,good energy saving effect,take the daily processing capacity of 5T/D model as an example,installed power is 117kw. |
2 |
Low operating temperature and slow heat loss:if microwave and the ordinary heating have the same amount of sterilization effect,the temperature on the object is obviously lower than that of ordinary heating.Waste after microwave sterilization,no residue,light damage. |
3 |
Non-selective effect on organisms:microwave has the same effect on organisms without selectivity,and its wide spectrum of bacteria can kill all kinds of microorganisms and pathogens. |
4 |
Microwave sterilization requires a small working environment and occupation area,the surrounding environment does not constitute high temperature,clean and hygienic. |
Customer visit our factory :
ZHITE Environmental Protection Technology Co., Ltd.is a comprehensive domestic enterprise with integrating scientific research and development,engineering design,production and installation and commissioning services.The main products are medical waste treatment equipment,diseased livestock and poultry harmless treatment equipment,household waste treatment equipment,kitchen waste treatment equipment,tail vegetable treatment equipment,sludge treatment equipment and all kinds of shredding equipment and other solid waste treatment products. Also can design and customize all kinds of efficient and practical equipment and production lines according to customer needs. Quality in mind, quantity in hand!High aspiration,long-term quality!We remain true to our original aspiration and forge ahead!Better Quality!--Our pursuit forever! |
Q1:What about the delivery?
We can offer our equipment by containers or bulk ship, just depend on your actual request.
Q2:What is the warranty?
We provide 1 year warranty and free repair if quality problems emerge within warranty peride.
Q3:What's the payment methode?
We can accept T/T, L/C, WESTERN UNION and so on.
Q4:Is it factory?
Yes,we have our own factory.And welcome to visit our factory.
Q5.Whether it can be customized according to customer requirements?
Yes,we can design according to customer's requirement,we have many kinds of model.
You can choose the suitable one
1 |
Professional team offer the profession service throughout . |
2 |
Professional salesmen and engineer can provide the precise design and timely and efficiency communication. |
3 |
All dredging machinery support our customers inspection . we can offer the passed product
All production parts must through the strict testing . |
4 |
Before production we can send the engineer to the on site to collect the information |
5 |
Product is finished we can send the maintain team and engineer to abroad until the all dredger working normally . |
6 |
We can free for training the local workers and all kinds of guidance . complex problems we can help customers to solve them when necessary we can send the engineer to foreign |