Small-Scale Horizontal Incinerator for Industrial Waste

Product Details
Customization: Available
After-sales Service: Life Long Service
Warranty: Two Years
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW
  Support payments in USD
Secure payments: Every payment you make on Made-in-China.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Secured Trading Service
Diamond Member Since 2024

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

In-stock Capacity
The supplier has In-stock capacity
Fast Delivery
The supplier can deliver the goods within 30 days
Quality Assurance
The supplier provides quality assurance
Raw-Materials Traceability
The supplier has traceability identification of raw materials
to see all verified strength labels (18)
  • Small-Scale Horizontal Incinerator for Industrial Waste
  • Small-Scale Horizontal Incinerator for Industrial Waste
  • Small-Scale Horizontal Incinerator for Industrial Waste
  • Small-Scale Horizontal Incinerator for Industrial Waste
  • Small-Scale Horizontal Incinerator for Industrial Waste
  • Small-Scale Horizontal Incinerator for Industrial Waste
Find Similar Products

Basic Info.

Model NO.
AEH-70
Condition
New
Certification
GMA, QS, FDA, ISO, CE
Automation
Automatic
Screw
Multi-Screw
Treatment
Pyrolysis
The Delivery Date
30 Days After Receipt of Payment
Type
Incineration Equipment
Main Equipment Size(mm)
2900*2500*1500
Processing Capacity(Kg/Batch)
70
Incinerator Volume
12
Power Consumption(Kw/H)
10-30
Oil Consumption(L/H)
10-40
Physical Weighing(T)
15-25
Transport Package
Wooden Box
Specification
5t/day
Trademark
Aoerheng
Origin
China
HS Code
8417809090
Production Capacity
50000 Sets / Year

Product Description

                                     Small-scale horizontal incinerator for industrial waste
 

1.product introduction :
Incinerators can destroy and remove at least 99.99% of each hazardous chemical substance in the waste they treat. When there are some extremely harmful chemicals, the incinerator is required to eliminate and remove at least 99.9999% of the pollutants in the waste. Ash remaining at the bottom of the combustion chamber may need to be disposed of in a hazardous waste landfill
 

Small-Scale Horizontal Incinerator for Industrial Waste
Small-Scale Horizontal Incinerator for Industrial Waste

 

2. Technical parameters of incinerator:
 

1. Calorific value of incinerator: the mixed calorific value is less than 4500kcal / kg
2. Equipment handling capacity: 500kg / h
3. Ignition mode: automatic ignition
4. Auxiliary fuel: diesel (low calorific value 10495kcal / kg)
5. Incinerator structure: direct combustion furnace
6. Temperature of primary combustion chamber: ≥ 800 ºC
7. Temperature of secondary combustion chamber: ≥ 1100 ºC

8. Flue gas outlet temperature of primary combustion chamber ≥ 850 ºC
 
9. Incinerator body surface temperature ≤ 35 ºC

10. Oxygen content of outlet flue gas (dry flue gas): 6% - 10%
 
11. Pressure in the furnace: negative pressure design, no counter fire, and - 3 ~ - 10mmh2o column
12. Burning rate of incineration residue gt; 5%
13. The furnace body is well sealed, and the feed furnace door adopts sealing structure to avoid gas leakage.

3.Equipment composition :
 

Small-Scale Horizontal Incinerator for Industrial Waste
                              Main furnace

burning main chamber ,cavity adopts high temperature refractory materials such as refractory cement .


The temperature reaches350degrees celsius to melt,the temperature reaches 750degrees celsius completely burning

                    

 

  
Small-Scale Horizontal Incinerator for Industrial Waste
                  Electrical controi cabinet 

 it is controlled by frequency converter regulator to realize open

circuit and open circuit through high and low frequency, protect the

circuit and realize one key operation
                  Secondary combustion chamber

 in order to fully mix the flue gas with the secondary air supply, the secondary combustion chamber adopts a high secondary wind speed, which is arranged downward at different heights.

The secondary air forms an imaginary circle in the center of the secondary combustion chamber, the flue gas rises spirally driven by the secondary air, and the flue gas flow stroke is lengthened, so that the furnace space of the secondary combustion chamber is fully utilized, The residence time of flue gas in the secondary combustion chamber is prolonged, and the residence time of flue gas is 3.5s, so that the harmful substances in the flue gas are completely decomposed
Small-Scale Horizontal Incinerator for Industrial Waste
Small-Scale Horizontal Incinerator for Industrial Waste
                                  Quench device

An exhaust gas buffer device, a quench tower and an induced draft fan, and the induced draft fan, the exhaust gas buffer device and the quench tower are successively connected through a connecting pipe string;



The waste gas buffer device ensures that the incineration waste gas is provided to the quench tower for treatment slowly and uniformly, and then the waste gas is quenched through the quench tower, which can effectively treat the waste gas generated after high-temperature incineration, and solve the problems of environmental pollution, energy conservation and environmental protection.
                 Cyclone dry dedusting

A dust removal device that uses the centrifugal force generated by the rotating air flow to separate dust particles from the combined dust air flow

(Water film dust removal.   Deacidification unit.   Activated carbon plant.  Nitrate lime injection device.   photocatalysis.  Bag filter)
Small-Scale Horizontal Incinerator for Industrial Waste
Small-Scale Horizontal Incinerator for Industrial Waste
                   Induced draft fan

          
  guide clean air to the chimney
                                       Chimney

                          clean tail gas discharge device
Small-Scale Horizontal Incinerator for Industrial Waste

4.Tail gas reference standard:
The pollution control standard for hazardous waste incineration (GB18484-2001) of the State Environmental Protection Administration was implemented on January 1, 2001. The allowable concentration of pollutants discharged from flue gas is as follows:
 

number contaminants Maximum allowable emission concentration limit under different incinerator capacity(mg/m3)

       ≤300(Kg/h)                         300~2500(Kg/h                                          ≥2500(Kg/h)                                                        
 
1 Smoke blackness Ringerman level1  
2 Smoke 100                                      80                                     65  
3 Carbon monoxide 100                                      80                                     80  
4 Sulfur dioxide 400                                      300                                    200  
5 Hydrogen fluoride 9.0                                        7.0                                    5.0  
6 Hydrogen chloride 100                                        70                                    60  
7 Nitrogen oxide 0.1  
8 Mercury and its compounds 500  
9 Cadmium and its compounds 0.1  
10 Arsenic nickel and their compounds 1.0  
11 Lead and its compounds 1.0  
12 Chromium,tin,antimony,copper,manganese,and their compounds 4.0  
13 Dioxins 0.5TEQ  ng/m3  
 4.Specification parameter table:
 

Serial number
 
Specification and model Main equipment size Processing capacity
(kg/batch)
incinerator volume
(m2)
Power  consumption
(kw/h)
oil wear
(l/h)
Equipment weighing
(t)
 
        1 AEHA-25 1000*900*1700 25 2.5 2 3 1.15  
        2 AEHA-20-40 1200*1300*1800 20-40 3.0 2-4 3-8 2.2-5.5  
        3 AEHA-20-60 1700*1500*2100 20-60 5.0 2-5 3-10 4.5-7.8  
        4 AEHA-50-120 2200*2000*2500 50-120 10.0 3-12 4-15 5.0-11.5  
        5 AEHA-100-300 3000*3500*2900 100-300 13.0 10-30 10-40 15-25  
   
       6

 
AEHA-400-500 3000*3700*3200 400-500 17.0 40-50 50-60 30-45  

5.Our transportation:
Small-Scale Horizontal Incinerator for Industrial WasteSmall-Scale Horizontal Incinerator for Industrial Waste
6.Our factory:

AEHA series harmless incinerator is a domestic and international harmless incineration treatment equipment developed by introducing Japanese

harmless incinerator technology, organizing technical public relations, sublating the advantages and disadvantages of similar equipment at home

and abroad. The equipment has the characteristics of small volume, incineration, reasonable process, technology and high degree of

harmlessness. It is an ideal waste treatment equipment for all kinds of hospitals, hotels, stations, sanitation stations, laboratories and farms.
 

Small-Scale Horizontal Incinerator for Industrial Waste   AOERHENG company covers an area of 20000 square meters. The company adopts modern enterprise management concept. seiko manufacturing. forge ahead. the product quality is superior to the domestic and foreign counterparts products.

 Company technical force is abundant. the craft is advanced. complete range of articles. in strict accordance with ISO9001 standards. organization.design. production.sales and management.

 Company sets scientific research and development. engineering design. installation. debugging. production services for the integration of domestic comprehensive backbone enterprises.

Products with free-pollution disposal equipment. garbage disposal equipment. high concentration wastewater treatment equipment. organic fertilizer production equipment. air treatment equipment.

Sludge treatment equipment. automobile processing equipment such as environmental protection equipment . And can design according to customer demand.

Customization of all kinds of efficient and practical equipment and production line.


7.Our services:


pre-sale
 

1. Selection of equipment model.

2. Design and manufacture products according to the special requirements of customers.

3. The manufacturer shall send engineers and technicians to inspect the site free of charge.

sale


1. Product acceptance.

2. Assist the customer to formulate the construction scheme.

after-sales

1. Free guidance on equipment installation and commissioning

2. Train technical personnel for customers

3. On site training for operators

 




 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now