Customization: | Available |
---|---|
After-sales Service: | Lifelong |
Warranty: | 2 Year |
Still deciding? Get samples of $ !
Order Sample
|
Shipping Cost: | Contact the supplier about freight and estimated delivery time. |
---|
Payment Methods: |
![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() |
---|---|
Support payments in USD |
Secure payments: | Every payment you make on Made-in-China.com is protected by the platform. |
---|
Refund policy: | Claim a refund if your order doesn't ship, is missing, or arrives with product issues. |
---|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
2.Introduction to grate:
3. Characteristic:
1. Automatic feeding and discharging system is set to avoid possible pollution caused by manual operation; | |||||||||
2. Secondary combustion design, the temperature in the furnace is above 1100 ºC ~ 1300 ºC, the flue gas is reprocessed, colorless, the combustibles are completely ashed, and the volume reduction ratio is ≥ 97%; | |||||||||
3. Small furnace volume and small equipment floor area | |||||||||
4. Design safety chain pin, two-level temperature control automatic alarm system, low operation cost and high degree of automation. | |||||||||
5. The full-automatic control technology is adopted to monitor and control the important parameters of the incineration process, with a high degree of automation. |
4. Product parameters:
Serial number |
Specification and model | Main equipment size | Processing capacity (kg/batch) |
incinerator volume (m2) |
Power consumption (kw/h) |
oil wear (l/h) |
Equipmentweight (t) |
1 | HRXS-25 | 1000*900*1700 | 25 | 2.5 | 2 | 3 | 1.15 |
2 | HRXS-20-40 | 1200*1300*1800 | 20-40 | 3.0 | 2-4 | 3-8 | 2.2-5.5 |
3 | HRXS-20-60 | 1700*1500*2100 | 20-60 | 5.0 | 2-5 | 3-10 | 4.5-7.8 |
4 | HRXS-50-120 | 2200*2000*2500 | 50-120 | 10.0 | 3-12 | 4-15 | 5.0-11.5 |
5 | HRXS-100-300 | 3000*3500*2900 | 100-300 | 13.0 | 10-30 | 10-40 | 15-25 |
6 | HRXS-400-500 | 3000*3700*3200 | 400-500 | 17.0 | 40-50 | 50-60 | 30-45 |
5.Tail gas reference standard:
Number | Contaminants | Maximum allowable emission concentration limit under different incinerator capacity(mg/m3) | ||
≤300(Kg/h) | 300~2500(Kg/h) | ≥2500(Kg/h) | ||
1 | Smoke blackness | Ringerman level1 | ||
2 | Smoke | 100 | 80 | 65 |
3 | Carbon monoxide | 100 | 80 | 80 |
4 | Sulfur dioxide | 400 | 300 | 200 |
5 | Hydrogen fluoride | 9.0 | 7.0 | 5.0 |
6 | Hydrogen chloride | 100 | 70 | 60 |
7 | Nitrogen oxide | 0.1 | ||
8 | Mercury and its compounds | 500 | ||
9 | Cadmium and its compounds | 0.1 | ||
10 | Arsenic nickel and their compounds | 1.0 | ||
11 | Lead and its compounds | 1.0 | ||
12 | Chromium,tin,antimony,copper,manganese,and their compounds | 4.0 | ||
13 | Dioxins | 0.5TEQ ng/m3 |
6.Our factory:
Pre-sale | |
1. | Selection of equipment model |
2. | Design and manufacture products according to the special requirements of customers. |
3. | The manufacturer shall send engineers and technicians to inspect the site free of charge. |
Sale | |
1. | Product acceptance. |
2. | Assist the customer to formulate the construction scheme. |
After-sales | |
1. | Free guidance on equipment installation and commissioning. |
2. | Train technical personnel for customers. |
3. | On site training for operators. |
8. Our qualifications :